OilGasDrillingFleet reference stack
Bench test
Pending bench test — Validation status.
Drilling / workover SCADA. Device type: drilling_rig.
New widget: drillingMonitoring (depth, WOB, RPM, ROP, torque, SPP, hook load, mud, status).
Telemetry contract
| Key | Unit | Meaning |
|---|---|---|
drill_status | string | DRILLING / CONNECTION / … |
drill_bit_depth_m / drill_hole_depth_m | m | Bit / hole |
drill_wob_kn | kN | Weight on bit |
drill_rpm | rpm | Rotary |
drill_rop_mh | m/h | Rate of penetration |
drill_torque_knm | kN·m | Torque |
drill_spp_bar | bar | Standpipe pressure |
drill_hook_load_kn | kN | Hook load |
drill_mud_flow_lpm / drill_mud_density_sg | L/min, SG | Mud |
drill_stand_count | count | Stands |
Reference hardware (pending)
| Role | Class | Protocol |
|---|---|---|
| Rig EDR / WITS | Electronic drilling recorder | WITS / WITSML → edge → MQTT |
| Sensors | Load cells, encoders, pressure, flow | Modbus / OPC-UA → edge |
| Mud skid | Density / flow meters | Modbus TCP |
Connectivity options
| Profile | Edge | Link | Status |
|---|---|---|---|
| P2 | Rig edge computer (Linux/IPC) | Ethernet / 4G MQTT | Pending |
| P3 | OPC-UA / Modbus TCP plant net | Ethernet | Pending |
| P4 | EDR cloud bridge MQTT | LTE / VSAT | BYO |
| P1 | Remote Modbus over cellular DTU | 4G | Pending |
Wiring — rig edge
mermaid
flowchart LR
AC[Autoconnecto]
EDGE[Rig edge GW]
EDR[EDR / WITS]
MUD[Mud system]
AC <-->|MQTT| EDGE
EDGE --> EDR
EDGE --> MUDNormalize vendor tags to drill_* keys in edge or Integration Hub.
Related
- Connectivity profiles · GeneratorFleet (similar panel widget pattern)