Reference stacks ​

A reference stack is a complete field path for a Solution: sensor or controller → edge connectivity → Autoconnecto device/gateway → telemetry keys the dashboard expects.

Solutions share one UX spine (Solution dashboard template). Reference stacks add variety without forking dashboards.

Bench test tracker (what is proven today): Validation status — EnergyFleet and ClimateFleet primary P1 paths are bench tested; Phase 1 fleets are documented and pending bench test until lab/field runs complete.

How to read the matrix ​

StatusMeaning
Bench testedEnd-to-end on Autoconnecto with the named hardware path (see validation status).
Pending bench testDatasheet-aligned wiring and register/key mapping documented; not yet fully exercised on our hardware.
BYO devicePublish the listed keys (any profile) — widgets work without a named SKU.

Connectivity profile IDs (P1–P6) are defined in Connectivity profiles.

Catalog matrix ​

SolutionDevice typeStack docBench test (primary path)
EnergyFleetenergy_meterEnergyFleetTested — P1 AVH-14-M1 + 4G DTU
ClimateFleetht_sensorClimateFleetTested — P1 XY-MD02 + 4G DTU
FuelFleetfuel_tankFuelFleetPending — P1 / P2 ultrasonic Modbus
WaterFleetwater_meterWaterFleetPending — P1 / P2 EM flow + pressure
GeneratorFleetgeneratorGeneratorFleetPending — controller Modbus
AirQualityFleetair_qualityAir qualityPending — P2 / P4 IAQ
ColdChainFleetcold_chainCold chainPending — probe + door

Phase 2 (index) ​

SolutionDevice typeStack docBench test
SmartOfficeFleetsmart_officesmart-office-fleetPending
SmartRetailFleetsmart_retailsmart-retail-fleetPending
SmartHomeFleetsmart_homesmart-home-fleetPending
SiteTrackingFleetsite_trackersite-tracking-fleetPending
AssistedLivingFleetassisted_livingassisted-living-fleetPending
WasteManagementFleetwaste_binwaste-management-fleetPending
SmartIrrigationFleetirrigation_zonesmart-irrigation-fleetPending

Phase 3 (index) ​

SolutionDevice typeStack docBench test
PoolScadaFleetpool_controllerpool-scada-fleetPending
OilGasDrillingFleetdrilling_rigoil-gas-drilling-fleetPending
EntityManagementFleetmanaged_entityentity-management-fleetPending
EnergyScadaFleetenergy_scadaenergy-scada-fleetPending

Phase 4 + Analytics (index) ​

SolutionDevice typeStack docBench test
PumpStationFleetpump_stationpump-station-fleetPending
SolarInverterFleetsolar_invertersolar-inverter-fleetPending
UpsBatteryFleetupsups-battery-fleetPending
HvacChillerFleetchillerhvac-chiller-fleetPending
ColdChainVehicleFleetreefer_vehiclecold-chain-vehicle-fleetPending
EnergyAnalyticsenergy_meterenergy-analyticsPending
FleetHealthAnalyticsht_sensorfleet-health-analyticsPending
UtilizationAnalyticsgeneratorutilization-analyticsPending

Phase 5 — Analytics B (index) ​

SolutionDevice typeStack docBench test
PumpAnalyticspump_stationpump-analyticsPending
SolarAnalyticssolar_invertersolar-analyticsPending
UpsAnalyticsupsups-analyticsPending
ChillerAnalyticschillerchiller-analyticsPending
WaterAnalyticswater_meterwater-analyticsPending
FuelAnalyticsfuel_tankfuel-analyticsPending

Phase 6 — Analytics C (index) ​

SolutionDevice typeStack docBench test
ColdChainAnalyticscold_chaincold-chain-analyticsPending
AirQualityAnalyticsair_qualityair-quality-analyticsPending
IrrigationAnalyticsirrigation_zoneirrigation-analyticsPending
WasteAnalyticswaste_binwaste-analyticsPending
AlarmNoiseOpsht_sensoralarm-noise-opsPending

Telemetry contract rule ​

All profiles for a Solution must publish the same key names (units documented per stack). If your hardware uses different names, map them in a rule chain or integration before the dashboard sees data.