Appearance
Plant OEE
PlantOee is a Solution board for one machine: the OEE widget plus related count and current keys. Sample On feeds demo telemetry. Use copies a clean dashboard without the demo devices.
What you see
| Widget | Role |
|---|---|
| OEE | Availability (on-load vs planned hours), performance (cycles vs expected), quality (good_count / reject_count) |
| Machine Fleet Runtime | Load from machine_current_a when thresholds are set on the board |
| Value cards | Cycle / good / reject counts |
Quality stays blank until both good and reject counts are present. Performance needs shared attribute machine_expected_cycles_per_hour on the device. No counts are invented.
Telemetry keys (Sample On)
machine_load_state—on_load/idle/offmachine_cycle_count,good_count,reject_countmachine_current_a
Field path
Flash a plant sketch that publishes those keys, or start from Machine_Runtime_mqtt for current and add cycle/good/reject when you have them. Open Solutions → PlantOee → Sample On, then Use when you bind your own device.
Related
- Plant operations guide
- Machine Fleet Runtime
- Left-bar OEE was removed; use this Solution or add the OEE widget to any dashboard