Skip to content

Reference stack validation status ​

Reference stacks are published before every path is bench-tested. Use this page to see what Autoconnecto has already run on hardware versus what is documented from datasheets and waiting for bench sign-off.

You do not need to bench-test every Solution yourself to use the dashboards — create devices, publish the telemetry keys, and the fleet widgets work. Named BOMs and wiring diagrams are guidance; status below tells you how much end-to-end proof exists today.

Last updated: manual — change this table when a path completes bench test.


Status labels ​

LabelMeaning
Bench testedSensor/controller + edge + Autoconnecto (gateway/child or device MQTT) exercised; telemetry matches the Solution widgets.
Pending bench testRegister map, wiring, and steps follow manufacturer docs; not yet fully run on Autoconnecto hardware in our lab/field.
BYONo named SKU required — any device that publishes the Solution keys.

Solution summary ​

SolutionOverallBench-tested pathPending bench test
EnergyFleetPrimary path testedP1 — AVH-14-M1 + cellular DTU (MQTT serial)P2 ESP32 WiFi, P3 Ethernet Modbus TCP, P4 native MQTT
ClimateFleetPrimary path testedP1 — XY-MD02 + cellular DTU (MQTT serial)P2 ESP32 WiFi, P4 native MQTT
FuelFleetPending—P1 4G + ultrasonic Modbus, P2 ESP32, P4 LTE level sensor
WaterFleetPending—P1 4G EM flow + pressure, P2 ESP32, P3 Modbus TCP
GeneratorFleetPending—P1/P2/P3 genset controller Modbus (e.g. DSE class)
AirQualityFleetPending—P1 Modbus IAQ, P2 ESP32 composite, P4 WiFi IAQ MQTT
ColdChainFleetPending—P1 4G probe + door IO, P2 ESP32, P4 reefer MQTT

Phase 2 (all pending bench test) ​

SolutionBench testStack
SmartOfficeFleetPendingsmart-office-fleet
SmartRetailFleetPendingsmart-retail-fleet
SmartHomeFleetPendingsmart-home-fleet
SiteTrackingFleetPendingsite-tracking-fleet
AssistedLivingFleetPendingassisted-living-fleet
WasteManagementFleetPendingwaste-management-fleet
SmartIrrigationFleetPendingsmart-irrigation-fleet

Index: Phase 2. Phase 1: Reference stacks.

Phase 3 (all pending bench test) ​

SolutionBench testStack
PoolScadaFleetPendingpool-scada-fleet
OilGasDrillingFleetPendingoil-gas-drilling-fleet
EntityManagementFleetPendingentity-management-fleet
EnergyScadaFleetPendingenergy-scada-fleet

Index: Phase 3. New widgets: poolWaterQuality, drillingMonitoring.

Phase 4 + Analytics (all pending bench test) ​

SolutionBench testStack
PumpStationFleetPendingpump-station-fleet
SolarInverterFleetPendingsolar-inverter-fleet
UpsBatteryFleetPendingups-battery-fleet
HvacChillerFleetPendinghvac-chiller-fleet
ColdChainVehicleFleetPendingcold-chain-vehicle-fleet
EnergyAnalyticsPendingenergy-analytics
FleetHealthAnalyticsPendingfleet-health-analytics
UtilizationAnalyticsPendingutilization-analytics

Index: Phase 4.

Phase 5 — Analytics B (all pending bench test) ​

SolutionBench testStack
PumpAnalyticsPendingpump-analytics
SolarAnalyticsPendingsolar-analytics
UpsAnalyticsPendingups-analytics
ChillerAnalyticsPendingchiller-analytics
WaterAnalyticsPendingwater-analytics
FuelAnalyticsPendingfuel-analytics

Index: Phase 5.

Phase 6 — Analytics C (all pending bench test) ​

SolutionBench testStack
ColdChainAnalyticsPendingcold-chain-analytics
AirQualityAnalyticsPendingair-quality-analytics
IrrigationAnalyticsPendingirrigation-analytics
WasteAnalyticsPendingwaste-analytics
AlarmNoiseOpsPendingalarm-noise-ops

Index: Phase 6.


Analytics hub (software smoke) ​

Forecast, z-score anomalies, asset rollups, and shared views are validated via UI/API smoke — not hardware bench. Checklist: Field validation. Hub overview: Analytics hub.


Device integration guides (field) ​

GuideBench test
USR-DR154 Modbus MQTTTested (ClimateFleet P1 path)
Multispan AVH-14-M1Tested (EnergyFleet P1 path)
ESP32 Modbus edgePending (pattern doc only; reuse XY-MD02/AVH maps in firmware when testing)

When a path moves to “Bench tested” ​

  1. Complete wiring per stack doc and manufacturer manual.
  2. Confirm telemetry keys and values on the child/device in Autoconnecto (not only on the gateway).
  3. Spot-check dashboard widgets and alarms on the Solution preview or a copy.
  4. Update this page and the profile row on the Solution stack doc.

No fixed schedule — update as lab/field capacity allows.