Skip to content

SmartMeteringFleet ​

Utility / AMI-style smart metering fleet. Device type: smart_meter.

Use this when the story is interval meter reads and a rising cumulative kWh register (residential or light commercial meters). For industrial 3-phase panel meters (AVH-class power quality), use EnergyFleet instead.


Telemetry contract ​

KeyUnitNotes
energy_kwh_cumkWhCumulative billing register (monotonic)
active_power_kwkWInstantaneous active power
voltage_vVLine voltage (single-phase utility shape)
current_aALine current
frequency_hzHzGrid frequency
power_factor—0–1

Field vs Sample On ​

Field deploymentSample On (demo)
Report cadenceTypically every 15 minutes (report_interval_sec = 900 on the device SERVER attributes)About every 5 seconds so the live demo moves
EnergyCumulative register advances with loadSame counter behaviour, accelerated for the demo

Sample rate is not limited by your plan’s minimum telemetry interval. Retention follows your plan like any other device.


SERVER attributes (seeded on Sample devices) ​

AttributeExampleMeaning
report_interval_sec900Declared AMI report period (15 minutes)
sanctioned_load_kw10Contracted / sanctioned load
voltage_high_limit / voltage_low_limit250 / 200DYNAMIC alarm limits
current_high_limit55DYNAMIC alarm limit
pf_low_limit0.85DYNAMIC alarm limit

How to demo ​

  1. Open Solutions → SmartMeteringFleet.
  2. Turn Sample On.
  3. Confirm home counts, active/inactive lists, and meter detail show rising Cumulative energy and live power / voltage / current.
  4. Open a demo meter’s attributes and show report_interval_sec = 900 (15-minute field cadence).

Use copies a clean dashboard — bind your own smart_meter devices; Sample devices are not copied.


support@autoconnecto.in · founder@autoconnecto.in · +91 92121 00555 · app.autoconnecto.in